IEC Inlet Power Line Filters

Payment Type: T/T
Incoterm: FOB,CFR,CIF,EXW
Min. Order: 2 Piece/Pieces
Delivery Time: 7 Days

Basic Info

Model No.: FT110I-D

Operating Frequency: 50/60Hz

Climatic Category(IEC 60068-1): 25/085/21(-25℃ /+85℃ Damp Heat Test For 21 Days)

Rated Voltage: 110/250VAC

Rated Current: 1-10A@40℃

Test Voltage: 1500VDC, 3S(line-line); 1500VAC, 3S(line-ground)

Additional Info

Packaging: Carton

Productivity: 500,000pcs annually

Brand: FILTEMC

Transportation: Ocean,Air

Place of Origin: Jinan

Certificate: ISO9001, CE, UL, TUV, RoHS

HS Code: 8548900001

Port: Qingdao,Tianjin,Beijing

Product Description

Introduction of IEC Power Line Filters

Rated current: 1~10A

Standard IEC inlet with switch and two fuses at the input end

Wire or solder lug terminals at the output end

Optional medical versions(H type)

Custom specific versions available on request


Features and Beneifits of IEC Inlet Power Line Filters :

  • Specially designed for standard IEC connector,fast and simple mounting, highly cost effective. 
  • With oneφ5x20mm F type glass fuse, and 1-pole rocker switch. 
  • FT110I-d series are general purpose one-stage common mode filters. 
  • Excellent attenuation performance for interference from 150KHz to 30MHz.


Typical Applications of IEC Inlet Power Line Filters :

  • IT, telecommunication equipment 
  • Instruments and meters 
  • Household small tools 
  • Test and measurement equipment 
  • Electronic equipment requiring connection of standard plug


EMI Filter certificates CE RoHS UL


Technical Data of IEC Inlet Power Line Filters :

FT110I-D EMI Filters


1. Storage of DC EMI Filters: 

  •  The DC Power Line Filters mustn't be left out in the heat of the sun or exposed to the rain, it should be stored in warehouse with good ventilation, surrounding temperature between -30℃ and +65℃ , the highest relative air humidity lower than 90%, and no corrosive liquid or gas.

2. Installation of DC Power Line Filters:  

  • DC EMI Filters should be installed at power input, and the line inside the chassis be as short as possible to reduce radiated interference. 
  • Both input and output lines of Inverter filters neither be intersected nor be tied up by string.
  • Make sure the mounting flange fully grounded, and keep the ground cable as short as possible if filters are connected to other equipment. 
  • If the terminal is stud, please use two spanners to fasten the screw nut when connecting to avoid stud rotating and thus causing changes to the internal circuit and consequently leading to filters arcing, short circuit, broken down or the filtering effect worsened. 
  • First use spanner1 to fix the screw nut near the metal case, then use spanner2 to tighten the screw nut in front( shown as Figure1), otherwise the terminals may be damaged. 
  • Apply the same for the connection of other phases.


Requests for samples of any catalog item are available for engineering evaluation Free of Charge.

All EMI Filters are RoHS compliant and approvals held include CE, UL,cUL and TUV.

All quality control procedures are fully documented and available for review. FILTEMC is ISO 9001 compliant.



Contact Person: Cindy Suen

Phone:+86-531-58622885

Fax:+86-531-58622899

Address: Building 20, Xinmao Qilu Science and Technology City, No. 1 Zidong Road,Tianqiao District,,Jinan,Shandong

quick navigation

Sweep wechat

Sweep surprise

Phone:+86-531-58622885

Contact Us Now